Water Chiller Replacement in London

Water chillers can play a pivotal role in maintaining the optimal temperature in a wide range of commercial, healthcare or industrial settings. Whether you run a manufacturing plant, which requires specific temperatures to be met for specific processes, a data centre, a hospital or even a research laboratory, getting the precise temperature control you need is essential for ensuring everything runs as you wish it to do.

Here at iClimate, we have developed a service that provides a range of clients with water chiller replacement in London premises. From the simple water chilling units required for a small-scale manufacturer to the critical temperature control requirements of a data centre, we can design systems to meet your needs, which provide a reliable and efficient way to ensure that  your premises are at optimal temperatures.

FIXED COST

Contact us today to start your water chiller replacment process

Precision Cooling for Your Premises or New Development

There are a variety of different types of business that may need to ensure optimal temperatures are maintained. From sensitive chemicals and compounds to delicate electronic equipment, a water chiller can be useful in removing heat from a space or even from a manufacturing process by calling the water supply linked to it.

When choosing a water chiller it is essential that efficiency and reliability are in-built. Here at iClimate, we work with some of the world’s most well-respected water chiller manufacturers, and have deep knowledge of how to get the best out of the systems you choose for your specific needs.

Water chiller installation for London Buildings

Clients that may require water chiller installation in London include manufacturers who require precise temperature control to guarantee product consistency and quality. Or, data centres that cannot afford to allow servers to overheat, as precise temperatures in IT infrastructure can help ensure optimal performance. Another type of client that may require this type of installation is the healthcare facility. Whether cooling medical equipment such MRI machines,maintaining optimal temperature in operating theatres, or providing the temperature control a lab needs to operate optimally, there are a range of systems that can be sourced to suit your needs.

What water chiller solutions can I opt for?

There are a variety of different types of water chiller solutions, and great care needs to be taken to ensure you get the right system for you. Introducing 

Air-cooled chillers

This type of chiller uses ambient air to reduce heat. It can be suitable where there is limited water availability or where you need to prioritise the conservation of water. These chillers are typically seen sited outside on at roof level of buildings, or ducted within ventilated plantrooms. 

Screw chillers

Operating via a screw compressor, a screw chiller is perfect for high efficiency cooling. It is typically used for large scale industrial environments.

Watercooled chillers

This type of chiller uses a separate water source, for example a cooling tower, to disperse heat. Typically, these are more energy efficient than an air cooled chiller. These chillers are larger range in capacity and utilise centrifugal compressors providing a more compact footprint compared to air cooled, but with more noise generation! 

Centrifugal chillers

This type of chiller uses a centrifugal compressor. It is able to handle large cooling loads, and is typically the choice for larger buildings.

Scroll chillers

This type of chiller uses a scroll compressor. It is ideal for noise sensitive environments as it is known for its quiet operation and reliability.

Why choose iClimate for water chiller installation in London?

Here at iClimate, we have been working with HVAC systems for many years.Throughout our time in the industry, we have gained deep knowledge and experience. of installing water chillers in a variety of London properties. Our founders have been working on chilled water systems from the old Staged head semi hermetic compressors on r134A, a crude methodology but suited to those  times. We have seen compressor technology and the digitisation of refrigerant metering and superheat control move towards making larger capacity chillers a more dynamic system reacting faster to the varied heat/cool loads of newer occupied buildings. We understand the need for larger plant to operate efficiently in the search for meeting demand from higher water temps and condensing/evaporating temps!  We select the Chiller type and compressor technology around the buildings measured load demand, existing infrastructure and lifetime running costs! 

To learn more about water chiller installation services for London clients, contact our friendly team today. You can reach us on 020 3198 1101 at any time.

Thermocold R410A rooftop HVAC unit mounted on a red steel frame with visible piping and control box, set against an urban skyline.

What is Covered in Our Technical Chiller Replacement Survey>?

There are many factors to consider when replacing your old water chiller plant, below are some the basic aspects we cover in our Technical Chiller Replacement Survey. 

Chiller brand/ Variant/ Year of Manufacture/ Condition, Breakdown History, and current measured performance. 

Condition Analysis of Compressors, Evaporator, Condenser and controls, parts availability and current/upcoming refrigerant legislations.

Comparing key original operating parameters of building VS current Building load demands, along with building hydronic system or Fan coils affecting new chiller performance. 

Existing System integration to new Chiller Plant

Chiller units are designed to supply CHW flow to Fan Coil units , AHUS through the buildings Chilled water pipework, pumps and valves, not forgetting the BMS control system. iClimates strong industrial background engineering design consultantancy means there isnt a building hvac design layout we have not mechanically designed all the way through to our onsite engineers maintaining.

BMS CONTROL PANEL

New Chiller Plant location

Scroll to Top